Standard

IEC 60730-2-9:2015+AMD1:2018 CSV

Identifier
IEC 60730-2-9:2015+AMD1:2018 CSV
Title
Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing control
Type of Document
Standard
Publisher
Edition Date
2018-03-02
Summary

IEC 60730-2-9:2015+A1:2018 applies to automatic electrical temperature sensing controls for use in, on or in association with equipment, including electrical controls for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This standard is applicable to automatic electrical temperature sensing controls forming part of a building automation control system within the scope of ISO 16484.

ES Main Coverage
Site, Building and Enclosure Coverage
Project Stage

IEC 60730-2-14:2017 RLV

Identifier
IEC 60730-2-14:2017 RLV
Title
Automatic electrical controls - Part 2-14: Particular requirements for electric actuators
Type of Document
Standard
Publisher
Country Coverage
Edition Date
2017-08-25
Summary

IEC 60730-2-14:2017 is available as IEC 60730-2-14:2017 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.IEC 607

ES Main Coverage
Site, Building and Enclosure Coverage
Project Stage

IEC 60730-2-15:2017

Identifier
IEC 60730-2-15:2017
Title
Automatic electrical controls - Part 2-15: Particular requirements for automatic electrical air flow, water flow and water level sensing controls
Type of Document
Standard
Publisher
Country Coverage
Edition Date
2017-08-17
Summary

IEC 60730-2-15:2017 applies to automatic electrical air flow, water flow and water level sensing controls for use in, or in association with, boilers with a maximum pressure rating of 2 000 kPA (20 bar) and equipment for general household and similar use including controls for heating, air-conditioning and similar applications.Examples are water flow and water level sensing controls of the float or electrode-sensor type used in boiler applications and air flow, water flow

ES Main Coverage
Site, Building and Enclosure Coverage
Project Stage

CAN/CSA-C22.2 NO. 62282-2:18

Identifier
CAN/CSA-C22.2 NO. 62282-2:18
Title
Fuel cell technologies — Part 2: Fuel cell modules (Adopted IEC 62282-2:2012, second edition, 2012-03, with Canadian deviations)
Type of Document
Standard
Edition Date
2018-04-01
Summary

This part of IEC 62282 provides the minimum requirements for safety and performance of fuel cell modules and applies to fuel cell modules with the following electrolyte chemistry:
– alkaline;
– polymer electrolyte (including direct methanol fuel cells) 1;
– phosphoric acid;
– molten carbonate;
– solid oxide;
– aqueous solution of salts.

Type of ES Technology
ES Main Coverage

CAN/CSA-C22.2 NO. 62282-3-100:15

Identifier
CAN/CSA-C22.2 NO. 62282-3-100:15
Title
Fuel cell technologies - Part 3-100: Stationary fuel cell power systems - Safety (Adopted IEC 62282-3-100:2012, first edition, 2012-02, with Canadian deviations)
Type of Document
Standard
Edition Date
2015-01-01
Summary

This part of IEC 62282 applies to stationary packaged, self-contained fuel cell power systems or fuel cell power systems comprised of factory matched packages of integrated systems which generate electricity through electrochemical reactions.
This standard applies to systems
- intended for electrical connection to mains direct, or with a transfer switch, or to a standalone power distribution system;
- intended to provide AC or DC power;
- with or without the ability to recover useful heat;

Type of ES Technology
ES Main Coverage

ANSI/CSA AMERICA FC 3-2004 (R2017)

Identifier
ANSI/CSA AMERICA FC 3-2004 (R2017)
Title
Portable Fuel Cell Power Systems
Type of Document
Standard
Edition Date
2017-01-01
Summary

1.1.1
This Standard applies to ac and dc type portable fuel cell power systems, with a rated output voltage not exceeding 600 V, for commercial, industrial, and residential indoor and outdoor use in non-hazardous locations, in accordance with the Rules of the National Electric Code, ANSI/NFPA 70.
1.1.2
This Standard does not apply to portable fuel cell power systems that are
a. Permanently connected (stationary) to either fuel or electric supply;
b. Designed to export power to the grid;

Type of ES Technology
ES Main Coverage

ANSI/CSA FC 1-2014

Identifier
ANSI/CSA FC 1-2014
Title
Fuel cell technologies - Part 3-100: Stationary fuel cell power systems - Safety (Adopted IEC 62282-3-100:12, first edition, 2012-02 with U.S. deviations)
Type of Document
Standard
Edition Date
2014-01-01
Summary

This part of IEC 62282 applies to stationary packaged, self-contained fuel cell power systems or fuel cell power systems comprised of factory matched packages of integrated systems which generate electricity through electrochemical reactions. 

Type of ES Technology
ES Main Coverage

IEC 62282-3-100:2012

Identifier
IEC 62282-3-100:2012
Title
Fuel cell technologies - Part 3-100: Stationary fuel cell power systems - Safety
Type of Document
Standard
Publisher
Edition Date
2012-02-16
Summary

IEC 62282-3-100:2012 is applicable to stationary fuel cell power systems intended for indoor and outdoor commercial, industrial and residential use in non-hazardous (unclassified) areas. It contemplates all significant hazards, hazardous situations and events, with the exception of those associated with environmental compatibility (installation conditions), relevant to fuel cell power systems, when they are used as intended and under the conditions foreseen by the manufacturer.

ISO 13766-2:2018

Identifier
ISO 13849-1:2015
Title
ISO 13766-2:2018 - Earth-moving and building construction machinery — Electromagnetic compatibility (EMC) of machines with internal electrical power supply — Part 2: Additional EMC requirements for functional safety
Type of Document
Standard
Edition Date
2015-12-01
2024-01-03
Summary

ISO 13849-1:2015 provides safety requirements and guidance on the principles for the design and integration of safety-related parts of control systems (SRP/CS), including the design of software. For these parts of SRP/CS, it specifies characteristics that include the performance level required for carrying out safety functions. It applies to SRP/CS for high demand and continuous mode, regardless of the type of technology and energy used (electrical, hydraulic, pneumatic, mechanical, etc.), for all kinds of machinery.

ES Main Coverage
Project Stage

ISO 13849-2:2012

Identifier
ISO 13849-2:2012
Title
ISO 13849-2:2012 - Safety of machinery — Safety-related parts of control systems — Part 2: Validation
Type of Document
Standard
Edition Date
2012-10-01
2023-09-04
Summary

ISO 13849-2:2012 specifies the procedures and conditions to be followed for the validation by analysis and testing of the specified safety functions, the category achieved, and the performance level achieved by the safety-related parts of a control system (SRP/CS) designed in accordance with ISO 13849-1.

ES Main Coverage