Performance

Description

References to documents related to the specifications of a component or a system and their assessments.

Distributed Generation Application Guideline, 2013

Identifier
Distributed Generation Application Guideline, 2013
Title
Distributed Generation Application Guideline, 2013
Type of Document
Guidance Document
Edition Date
2013 Jan 01
Summary

This guideline is primarily intended to provide an overview of the application process involved in becoming a distributed generator. If a prospective power plant owner plans to generate electric energy and the power plant capacity rating is less than one MW, the applicant may proceed without filing an application with the Alberta Utilities Commission (AUC) if the following three requirements are met: ? No person is directly and adversely affected. ? The power plant complies with AUC Rule 012: Noise Control (AUC Rule 012). ? There is no effect on the environment.

ES Main Coverage
Site, Building and Enclosure Coverage

ECG0008

Identifier
ECG0008
Title
Distributed System Voltage and Power Quality
Type of Document
Guidance Document
Edition Date
2016 Mar 09
Summary

The scope of this document is to provide guidelines for consistant and standard applications for voltage and power quality requirements on or connected to HOL’s distribution system. Normally voltage limits, voltage distortion, and current distortion are measured at the customer’s Point of Supply as per HOL document ECS0012. This document does not cover the following power quality issues: • Voltage control when the Independent Electrical System Operator (IESO) has declared a voltage reduction or an electrical system emergency; • Non-standard conditions such as a force majeure (e.g.

ECG0006

Identifier
ECG0006
Title
Embedded Generation Connection Guideline
Type of Document
Guidance Document
Edition Date
2005 Feb 02
Summary

This guideline is intended to assist the customer in understanding the connection process that results in connection of the customer's generation facility to Hydro Ottwwa's distribution network. This guideline does not provide all the details of costs or responsibilities that the customer may assume; such details will be evaluated for each specific request.

Canada-Wide Standards for Dioxins and Furans

Identifier
Canada-Wide Standards for Dioxins and Furans
Title
Canada-Wide Standards for Dioxins and Furans
Type of Document
Report
Edition Date
2001 May 01
Summary

The Canada-wide Standards process has focussed on anthropogenic sources that are releasing dioxins and furans to the atmosphere and soil in a continuous process.
In January 1999, the Federal/Provincial Task Force on Dioxins and Furans released the Dioxins and Furans and Hexachlorobenzene Inventory of Releases which documented the current understanding of anthropogenic sources in Canada releasing dioxins and furans. The Inventory of Releases lists emissions from over 20 sectors by province and territory, and provides national summaries for each sector.

ES Main Coverage
Site, Building and Enclosure Coverage

Canada-Wide Standards for Mercury Emissions

Identifier
Canada-Wide Standards for Mercury Emissions
Title
Canada-Wide Standards for Mercury Emissions
Type of Document
Report
Edition Date
2000 Jun 05
Summary

CCME recognizes the importance of continuous improvement in mercury emission reductions because of the toxic, persistent and bioaccumulative nature of this pollutant in order to protect not only fish and wildlife, but also human health. CCME is committed to reducing mercury releases to the environment. CCME developed Canada-wide Standards (CWSs) for mercury emissions from base-metal smelters, waste incinerators, coal-fired power plants as well as mercury-containing lamps and dental amalgam waste.

ES Main Coverage
Site, Building and Enclosure Coverage

PN 1076

Identifier
PN 1076
Title
National Guidelines for Hazardous Waste Incineration Facilities - Design and Operating Criteria
Type of Document
Guidance Document
Edition Date
1992 Mar 01
Summary

Properly designed and operated incineration systems are capable of destroying the hazardous organic components of a waste stream. On the Other hand, the improper design and operation of these systems could pose a threat to public health through emissions of hazardous and other contaminants including acid gases, metals and organics.
The inherent advantages of the thermal destruction of waste, balanced against the potential problems resulting from such practice, have led to the need to develop sound design and operating criteria for hazardous waste incineration facilities.

ES Main Coverage
Site, Building and Enclosure Coverage

IEC 60870-5-103:1997

Identifier
IEC 60870-5-103:1997
Title
Telecontrol equipment and systems - Part 5-103: Transmission protocols - Companion standard for the informative interface of protection equipment
Type of Document
Standard
Publisher
Edition Date
1997 Dec 11
Summary

Applies to protection equipment with coded bit serial data transmission for exchanging information with control systems. Defines a companion standard that enables interoperability between protection equipment and devices of a control system in a substation.
This publication is of high relevance for Smart Grid.

SAE J2572

Identifier
SAE J2572
Title
Recommended Practice for Measuring Fuel Consumption and Range of Fuel Cell and Hybrid Fuel Cell Vehicles Fueled by Compressed Gaseous Hydrogen.
Type of Document
Standard
Country Coverage
ES Main Coverage

IEC 62282-4-600 ED1

Identifier
IEC 62282-4-600 ED1
Title
Fuel cell technologies - Part 4-600: Fuel cell power systems for propulsion other than road vehicles and auxiliary power units (APU) - Fuel cell/battery hybrid systems performance test
Type of Document
Standard
Country Coverage