Switch Gear or Circuit Breakers
Category out of scope of this review, however kept as a place holder for relevant CSR and lesson-learned
UL 924
1.1 This Standard applies to emergency lighting and power equipment for use in unclassified locations and intended for connection to branch circuits 600 V or less. Intended to supply illumination, power or both automatically to critical areas and equipment in the event of failure of normal supply in accordance with NEC Article 700 or 701, NFPA 70, Life Safety Code, NFPA 101, Fire Code, NFPA 1, International Building Code (IBC) and International Fire Code (IFC).
AS/NZS - 3000 (2007)
The standard sets out requirements for the design, construction and verification of electrical installations, including the selection and installation of electrical equipment forming part of such electrical installations. These requirements are intended to protect persons, livestock, and property from electric shock, fire and physical injury hazards that may arise from an electrical installation that is used with reasonable care and with due regard to the intended purpose of the electrical installation.
AS 3011.2-1992
Specifies requirements for the installation of sealed secondary batteries permanently installed in buildings.
IEC 61000-6-1
There are various sub standards (6-1, 6.-2, etc.) that apply to EMC. Information from IEC 61000-6-1 covers EMC immunity requirements for electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists.
Data Sheet 5-19
The document describes switchgear as a general term covering switching, interrupting, control, metering, protective, and regulating devices and assemblies of these devices with their associated interconnections, accessories, and supporting structures and provides for the basic operation, protection, inspection, maintenance, and testing of various types of switchgear used in applications of at least 600V.
NFPA 70E
NFPA 70E requirements for safe work practices to protect personnel by reducing exposure to major electrical hazards. Originally developed at Occupational Safety and Health Administration (OSHA)’s request, NFPA 70E helps companies and employees avoid workplace injuries and fatalities due to shock, electrocution, arc flash and arc blast, and assists in complying with OSHA 1910 Subpart S and OSHA 1926 Subpart K.
UL 489
1.1 This standard covers molded-case circuit breakers, circuit-breaker and ground-fault circuit interrupters, fused circuit breakers and accessory high-fault protectors. These circuit breakers are specifically intended to provide service entrance, feeder and branch circuit protection in accordance with the National Installation Codes in Annex B, Ref. 1. This standard covers instantaneous-trip circuit breakers (circuit interrupters) specifically intended as part of a combination motor controller in accordance with the National Installation Codes in Annex B, Ref. 1.