Recommended Practice

IEEE Std 484-2002

Identifier
IEEE Std 484-2002
Title
IEEE Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications
Type of Document
Recommended Practice
Edition Date
2002-01-01
Summary

The recommended practice document provides recommended design practices and procedures for storage, location, mounting, ventilation, instrumentation, preassembly, assembly, and charging of VLA batteries. Required safety practices are also included. This document is applicable to full-float stationary applications where a battery charger normally maintains the battery fully charged and provides DC loads.

NFPA 70B

Identifier
NFPA 70B
Title
Recommended Practice for Electrical Equipment Maintenance
Type of Document
Recommended Practice
Edition Date
2016-01-01
Summary

1.1.1 This recommended practice applies to preventive maintenance for electrical, electronic, and communication systems and equipment and is not intended to duplicate or supersede instructions that manufacturers normally provide. Systems and equipment covered are typical of those installed in industrial plants, institutional and commercial buildings, and large multifamily residential complexes. 1.1.2 Consumer appliances and equipment intended primarily for use in the home are not included.

ES Main Coverage
Site, Building and Enclosure Coverage

IEEE Std 1547.6-2011

Identifier
IEEE Std 1547.6-2011
Title
IEEE Recommended Practice for Interconnecting Distributed Resources with Electric Power Systems Distribution Secondary Networks
Type of Document
Recommended Practice
Edition Date
2011-01-01
Summary

Recommendations and guidance for distributed resources (DR) interconnected on the distribution secondary networks, including both spot networks and grid networks, are provided. This document gives an overview of distribution secondary network systems design, components, and operation; describes considerations for interconnecting DR with networks; and provides potential solutions for the interconnection of DR on network distribution systems. IEEE Std 1547.6-2011 is part of the IEEE 1547™ series of standards.

ES Main Coverage
Site, Building and Enclosure Coverage

IEEE Std 1453-2015

Identifier
IEEE Std 1453-2015
Title
IEEE Recommended Practice for the Analysis of Fluctuating Installations on Power Systems
Type of Document
Recommended Practice
Edition Date
2015-10-30
Summary

Background on light flicker caused by fluctuations in power demands of variable loads is presented in this recommended practice. A flicker measurement method is presented using a meter that is completely described in IEC 61000-4-15. The short-term (Pst) and long-term (Plt) flicker indices used for the analysis of flicker data are defined. Flicker limits for various voltage levels are presented. An assessment procedure for evaluating flicker compliance against emission limits is described.

ES Main Coverage
Site, Building and Enclosure Coverage
Project Stage

ANSI/IEEE 1159-2009

Identifier
ANSI/IEEE 1159-2009
Title
IEEE Recommended Practice for Monitoring Electric Power Quality
Type of Document
Recommended Practice
Edition Date
2009-06-26
Summary

This Recommended Practice encompasses the monitoring of electrical characteristics of single-phase and polyphase ac power systems. It includes consistent descriptions of conducted electromagnetic phenomena occurring on power systems. The document describes nominal conditions and deviations from these nominal conditions that may originate within the source of supply or load equipment, or from interactions between the source and the load. Also, this document discusses power quality monitoring devices, application techniques, and interpretation of monitoring results.

ANSI/IEEE 1021-1988

Identifier
ANSI/IEEE 1021-1988
Title
IEEE Recommended Practice for Utility Interconnection of Small Wind Energy Conversion Systems
Type of Document
Recommended Practice
Edition Date
1987-11-30
Summary

Withdrawn standard. This recommended practice contains application guidelines and procedures for the interconnection and compatible operation of a SWECS with electric utilities. It addresses the interface between the wind system and the utility and the factors relating to equipment protection, power quality, and the safety of operating personnel and the general public.

ES Main Coverage
Site, Building and Enclosure Coverage
Project Stage

IEEE Std 1115-2014

Identifier
IEEE Std 1115-2014
Title
IEEE Recommended Practice for Sizing Nickel-Cadmium Batteries for Stationary Applications
Type of Document
Recommended Practice
Edition Date
2014-01-01
Summary

The sizing of nickel-cadmium batteries used in standby operation for stationary applications is discussed in this recommended practice

Type of ES Technology
ES Main Coverage
Project Stage

API RP 572

Identifier
API RP 572
Title
Inspection of Pressure Vessels
Type of Document
Recommended Practice
Edition Date
2016-12-01
Summary

Addresses the inspection of pressure vessels. It includes a description of the various types of pressure vessels and the standards that can be used for their construction and maintenance.

Type of ES Technology
ES Main Coverage
Project Stage