Grid Interconnection
Includes references for Interconnecting Energy Storage Systems with power grids
UL 9741
These requirements cover bidirectional electric vehicle charging equipment that charge electric vehicles from an electric power system and also include functionality to export power from the electric vehicle to an electric power system. When commanded, the bidirectional charging equipment exports electric power from the electric vehicle stored energy supply to the electric power system (EPS) to supply power to common loads.
CPUC Tariff Rule 21
Third parties must use certified equipment (both behind the meter and on the distribution grid) when attempting to interconnect new components to the grid. Certified equipment is equipment that has passed through rigorous certification testing procedures done by Nationally Recognized Testing Laboratories (NRTLs); UL is one such example. NRTLs create testing procedures for equipment that verify equipment functionality and safety to pre-set testing standards created by nationally recognized engineering groups such as IEEE.
IEC TS 62257-9-2:2016
The standard specifies the general requirements for the design and the implementation of micro grids used in decentralized rural electrification to ensure the safety of persons and property and their satisfactory operation according to the scheduled use.
NFPA 791
NFPA 791 covers recommended procedures for evaluating unlabeled electrical equipment for compliance with nationally recognized standards. Criteria provide guidance to third-party field evaluation bodies (FEBs) on how to perform evaluations of unlabeled electrical equipment in a consistent and reliable manner, thus assisting regulating authorities who make product and related installation approval decisions and facilitating acceptance of the results. Specific areas covered include pre-site preparation, construction inspection, electrical testing, and reporting, and documentation.
UL 6141
1.1 These requirements cover Wind Turbine Converter (WTC) products and assemblies. Some of the features and functions of these products include but are not limited to, generation of real and reactive power in parallel with the electric power system, EPS (electric utility grid), supplying power in a standalone operational mode, multiple mode operation, and bidirectional power flow operation with the EPS.
AS/NZS 4777.1:2016
This Standard specifies the electrical installation requirements for inverter energy systems and grid protection devices with ratings up to 10 kVA for single-phase units, or up to 30 kVA for three-phase units, for the injection of electric power through an electrical installation to the electricity distribution network. NOTES: 1 Although this Standard does not apply to larger systems, similar principles can be used for the installation of such systems. 2 This Standard does not cover detailed installation requirements for the energy source(s) and its associated wiring.
Data Sheet 5-19
The document describes switchgear as a general term covering switching, interrupting, control, metering, protective, and regulating devices and assemblies of these devices with their associated interconnections, accessories, and supporting structures and provides for the basic operation, protection, inspection, maintenance, and testing of various types of switchgear used in applications of at least 600V.
IEEE - C2-2017
This Code covers basic provisions for safeguarding of persons from hazards arising from the installation, operation, or maintenance of conductors and equipment in electric supply stations and overhead and underground electric supply and communication lines. It also includes work rules for the construction, maintenance, and operation of electric supply and communication lines and equipment. The standard is applicable to the systems and equipment operated by utilities, or similar systems and equipment, of an industrial establishment or complex under the control of qualified persons.