Testing, reliability & durability

IEC TS 62257-9-5:2016

Identifier
IEC TS 62257-9-5:2016
Title
Recommendations for renewable energy and hybrid systems for rural electrification - Part 9-5: Integrated systems - Selection of stand-alone lighting kits for rural electrification
Type of Document
Technical Specification
Publisher
Edition Date
2016 Jun 30
Summary

The document applies to stand-alone rechargeable electric lighting appliances or kits that can be installed by a typical user without employing a technician. This technical specification presents a quality assurance framework that includes product specifications a framework for interpreting test results test methods and standardized specifications sheets templates for communicating test results.

IEEE Std 1679-2010

Identifier
IEEE Std 1679-2010
Title
IEEE Recommended Practice for the Characterization and Evaluation of Emerging Energy Storage Technologies in Stationary Applications
Type of Document
Recommended Practice
Edition Date
2010 Jan 01
Summary

Standard covers recommended information for an objective evaluation of emerging energy storage technology by a potential user of any stationary application. Storage technologies are those that provide a means for the reversible storage of electrical energy (i.e., device receives electrical energy and can discharge electrical energy later). The storage medium may be electrochemical (e.g., batteries), kinetic (e.g., flywheels), electrostatic (e.g., electric double-layer capacitors [EDLCs]), thermal or other medium.

ISO 9001:2015

Identifier
ISO 9001:2015
Title
Quality management systems -- Requirements
Type of Document
Standard
Edition Date
2015 Sep 01
Summary

The ISO 9000 family addresses various aspects of quality management and contains some of ISO’s best known standards. The standards provide guidance and tools for companies and organizations who want to ensure that their products and services consistently meet customer’s requirements, and that quality is consistently improved.

NFPA 111

Identifier
NFPA 111
Title
Standard on Stored Electrical Energy Emergency and Standby Power Systems
Type of Document
Standard
Edition Date
2016 Jan 01
Summary

Readiness of emergency power is a key consideration in safeguarding building occupants in the event of a disruption of the normal utility supply. NFPA 111 covers performance requirements for stored electric energy systems providing an alternate source of electrical power in buildings and facilities during interruption of the normal power source.

AS 2676.1-1992

Identifier
AS 2676.1-1992
Title
Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings; Part 1: Vented cells
Type of Document
Guidance Document
Edition Date
1992 Jan 01
Summary

Abstract: Sets out recommended practices for the installation, maintenance, testing and replacement of vented secondary batteries permanently installed in buildings.
Scope:
This Standard sets out recommended practices for the installation, maintenance, testing and replacement of vented secondary batteries permanently installed in or on buildings. It also provides guidance to determine when batteries should be replaced.

IEC 61000-6-1

Identifier
IEC 61000-6-1
Title
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity standard for residential, commercial and light-industrial environments
Type of Document
Standard
Publisher
Country Coverage
Edition Date
2016 Aug 10
Summary

There are various sub standards (6-1, 6.-2, etc.) that apply to EMC. Information from IEC 61000-6-1 covers EMC immunity requirements for electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists.

ES Main Coverage
Site, Building and Enclosure Coverage

47 CFR 15.109

Identifier
47 CFR 15.109
Title
47 CFR Part 15, Subpart B - Unintentional Radiators, § 15.109 Radiated emission limits.
Type of Document
Regulation
Summary

(a) Except for Class A digital devices, the field strength of radiated emissions from unintentional radiators at a distance of 3 meters shall not exceed the following values:

Frequency of emission (MHz) Field strength (microvolts/meter)
30-88 100
88-216 150
216-960 200
Above 960 500

(b) The field strength of radiated emissions from a Class A digital device, as determined at a distance of 10 meters, shall not exceed the following:

Frequency of emission (MHz) Field strength (microvolts/meter)
30-88 90
88-216 150
216-960 210
Above 960 300

(c) In the emission tables above, the tighter limit applies at the band edges. Sections 15.33 and 15.35 which specify the frequency range over which radiated emissions are to be measured and the detector functions and other measurement standards apply.

(d) For CB receivers, the field strength of radiated emissions within the frequency range of 25-30 MHz shall not exceed 40 microvolts/meter at a distance of 3 meters. The field strength of radiated emissions above 30 MHz from such devices shall comply with the limits in paragraph (a) of this section.

(e) Carrier current systems used as unintentional radiators or other unintentional radiators that are designed to conduct their radio frequency emissions via connecting wires or cables and that operate in the frequency range of 9 kHz to 30 MHz, including devices that deliver the radio frequency energy to transducers, such as ultrasonic devices not covered under part 18 of this chapter, shall comply with the radiated emission limits for intentional radiators provided in § 15.209 for the frequency range of 9 kHz to 30 MHz. As an alternative, carrier current systems used as unintentional radiators and operating in the frequency range of 525 kHz to 1705 kHz may comply with the radiated emission limits provided in § 15.221(a). At frequencies above 30 MHz, the limits in paragraph (a), (b), or (g) of this section, as appropriate, apply.

(f) For a receiver which employs terminals for the connection of an external receiving antenna, the receiver shall be tested to demonstrate compliance with the provisions of this section with an antenna connected to the antenna terminals unless the antenna conducted power is measured as specified in § 15.111(a). If a permanently attached receiving antenna is used, the receiver shall be tested to demonstrate compliance with the provisions of this section.

(g) As an alternative to the radiated emission limits shown in paragraphs (a) and (b) of this section, digital devices may be shown to comply with the standards contained in Third Edition of the International Special Committee on Radio Interference (CISPR), Pub. 22, “Information Technology Equipment - Radio Disturbance Characteristics - Limits and Methods of Measurement” (incorporated by reference, see § 15.38). In addition:

(1) The test procedure and other requirements specified in this part shall continue to apply to digital devices.

(2) If, in accordance with § 15.33 of this part, measurements must be performed above 1000 MHz, compliance above 1000 MHz shall be demonstrated with the emission limit in paragraph (a) or (b) of this section, as appropriate. Measurements above 1000 MHz may be performed at the distance specified in the CISPR 22 publications for measurements below 1000 MHz provided the limits in paragraphs (a) and (b) of this section are extrapolated to the new measurement distance using an inverse linear distance extrapolation factor (20 dB/decade), e.g., the radiated limit above 1000 MHz for a Class B digital device is 150 uV/m, as measured at a distance of 10 meters.

(3) The measurement distances shown in CISPR Pub. 22, including measurements made in accordance with this paragraph above 1000 MHz, are considered, for the purpose of § 15.31(f)(4) of this part, to be the measurement distances specified in this part.

(h) Radar detectors shall comply with the emission limits in paragraph (a) of this section over the frequency range of 11.7-12.2 GHz.

[ 54 FR 17714, Apr. 25, 1989, as amended at 56 FR 373, Jan. 4, 1991; 58 FR 51249, Oct. 1, 1993; 66 FR 19098, Apr. 13, 2001; 67 FR 48993, July 29, 2002; 69 FR 2849, Jan. 21, 2004; 80 FR 33447, June 12, 2015]

Data Sheet 5-19

Identifier
Data Sheet 5-19
Title
Switchgear and Circuit Breakers
Type of Document
Report
Edition Date
2006 Jan 01
Summary

The document describes switchgear as a general term covering switching, interrupting, control, metering, protective, and regulating devices and assemblies of these devices with their associated interconnections, accessories, and supporting structures and provides for the basic operation, protection, inspection, maintenance, and testing of various types of switchgear used in applications of at least 600V.

ES Main Coverage
Site, Building and Enclosure Coverage

ICES-003

Identifier
ICES-003
Title
Information Technology Equipment (Including Digital Apparatus) — Limits and Methods of Measurement
Type of Document
Standard
Edition Date
2016 Jan 19
Summary

This Interference-Causing Equipment Standard–003 (ICES-003) sets out the technical requirements relative to radio noise generated by Information Technology Equipment (ITE).