CAN/CSA-E61558-2-4-03 (R2017)

Identifier
CAN/CSA-E61558-2-4-03 (R2017)
Title
Safety of Power Transformers, Power Supply Units and Similar - Part 2: Particular Requirements for Isolating Transformers for General Use (Adopted CEI/IEC 61558-2-4:1997, first edition 1997-02)
Type of Document
Standard
Edition Date
2017 Jan 01
Summary

Replacement:
This part 2 of IEC 61558 applies to stationary or portable, single-phase or polyphase, air-cooled isolating transformers, associated or otherwise, having a rated supply voltage not exceeding 1000 V a.c. and rated frequency not exceeding 500 Hz, the rated output not exceeding: - 25 kVA for single-phase transformers; - 40 kVA for polyphase transformers.

ES Main Coverage
Project Stage

CAN/CSA-E61558-2-6-03 (R2017)

Identifier
CAN/CSA-E61558-2-6-03 (R2017)
Title
Safety of Power Transformers, Power Supply Units and Similar - Part 2: Particular Requirements for Safety Isolating Transformers for General Use (Adopted CEI/IEC 61558-2-6:1997, first edition, 1997-02)
Type of Document
Standard
Edition Date
2017 Jan 01
Summary

Replacement:
This part 2 of IEC 61558 applies to stationary or portable, single-phase or polyphase, aircooled safety isolating transformers, associated or otherwise, having a rated supply voltage not exceeding 1000 V a.c. and rated frequency not exceeding 500 Hz, the rated output not exceeding: - 10 kVA for single-phase transformers; - 16 kVA for polyphase transformers.

ES Main Coverage
Project Stage

C22.2 NO. 0.23-15

Identifier
C22.2 NO. 0.23-15
Title
General requirements for battery-powered appliances
Type of Document
Standard
Edition Date
2015 Jan 01
Summary

This is the harmonized CSA Group and UL standard for General Requirements for Battery-Powered Appliances. It is the first edition of CSA C22.2 No. 0.23, and the second edition of UL 2595. This edition of UL 2595 supersedes the previous edition published on May 22, 2013.
Scope:

Type of ES Technology
ES Main Coverage

C381.2-17

Identifier
C381.2-17
Title
Energy performance of battery-charging systems and uninterruptible power supplies
Type of Document
Standard
Edition Date
2017 Jan 01
Summary

Preface:
This is the third edition of CSA C381.2, Energy performance of battery-charging systems and uninterruptible power supplies. It supersedes the previous editions published in 2014 and 2008 under the title, Test method for determining the energy efficiency of battery-charging systems.
This Standard specifies requirements, definitions, and test methods for determining the energy performance of battery-charging systems.
Scope:

Type of ES Technology
ES Main Coverage

CAN/CSA-C61427-1:17

Identifier
CAN/CSA-C61427-1:17
Title
Secondary cells and batteries for renewable energy storage — General requirements and methods of test — Part 1: Photovoltaic off-grid application (Adopted IEC 61427-1:2013, first edition, 2013-04, with Canadian deviations)
Type of Document
Standard
Edition Date
2017 Jan 01
Summary

This part of the IEC 61427 series gives general information relating to the requirements for the secondary batteries used in photovoltaic energy systems (PVES) and to the typical methods of test used for the verification of battery performances. This part deals with cells and batteries used in photovoltaic off-grid applications.
NOTE The part 2 of this series will cover cells and batteries used in "renewable energy storage in on-grid applications".

CAN/CSA-C22.2 NO. 60896-11:17

Identifier
CAN/CSA-C22.2 NO. 60896-11:17
Title
Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests (Adopted IEC 60896-11:2002, first edition, 2002-12, with Canadian deviations)
Type of Document
Standard
Edition Date
2017 Jan 01
Summary

This part of IEC 60896 is applicable to lead-acid cells and batteries which are designed for service in fixed locations (i.e. not habitually to be moved from place to place) and which are permanently connected to the load and to the d.c. power supply. Batteries operating in such applications are called "stationary batteries".



Any type or construction of lead-acid battery may be used for stationary battery applications. This part 11 of the standard is applicable to vented types only.



The object of this standard is to specify general requirements and the main characteristics, together with corresponding test methods associated with all types and construction modes of lead-acid stationary batteries, excluding valve-regulated types.



Recommendations on the use of tests for stationary battery application are given in Table A.1.



Recommendations relating the type of cell or monobloc to the use of tests are given in Table A.2.



Statements and claims of basic performance data by the manufacturer shall correspond to those tests.



The tests may also be used for type qualification. 

CAN/CSA-C22.2 NO. 60896-21:17

Identifier
CAN/CSA-C22.2 NO. 60896-21:17
Title
Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test (Adopted IEC 60896-21:2004, first edition, 2004-02, with Canadian deviations)
Type of Document
Standard
Edition Date
2017 Jan 01
Summary

This part of IEC 60896 applies to all stationary lead-acid cells and monobloc batteries of the valve regulated type for float charge applications, (i.e. permanently connected to a load and to a d.c. power supply), in a static location (i.e. not generally intended to be moved from place to place) and incorporated into stationary equipment or installed in battery rooms for use in telecom, uninterruptible power supply (UPS), utility switching, emergency power or similar applications.

Type of ES Technology
ES Main Coverage

CAN/CSA-C22.2 NO. 60896-22:17

Identifier
CAN/CSA-C22.2 NO. 60896-22:17
Title
Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements (Adopted IEC 60896-22:2004, first edition, 2004-02, with Canadian deviations)
Type of Document
Standard
Edition Date
2017 Jan 01
Summary

This part of IEC 60896 applies to all stationary lead-acid cells and monobloc batteries of the valve regulated type for float charge applications, (i.e. permanently connected to a load and to a d.c. power supply), in a static location (i.e. not generally intended to be moved from place to place) and incorporated into stationary equipment or installed in battery rooms for use in telecom, uninterruptible power supply (UPS), utility switching, emergency power or similar applications.

Type of ES Technology
ES Main Coverage

AS 2676.2-1992

Identifier
AS 2676.2-1992
Title
Guide to the installation, maintenance, testing and replacement of secondary batteries in buildings; Part 2: Sealed cells
Type of Document
Recommended Practice
Edition Date
1992 Jan 01
Summary

Abstract: Part 2 sets out recommended practices for the installation, maintenance, testing and replacement of sealed secondary batteries permanently installed in buildings.
Scope:

AS 3011.1-1992

Identifier
AS 3011.1-1992
Title
Electrical installations - Secondary batteries installed in buildings; Part 1: Vented cells
Type of Document
Standard
Edition Date
1992 Jan 01
Summary

Abstract: Specifies requirements for the installation of vented secondary batteries permanently installed in buildings.
Scope: