Pertinent
Identify if the document is pertinent for the particular element, or is relevant for information only.
IEC TR 62914:2014
IEC TR 62914:2014 identifies experimental procedures for the forced internal short-circuit tests in terms of designation, dimensions, tests and requirements. This technical report provides supplemental information to perform the forced internal short-circuit test of IEC 62133:2012 (Subclause 8.3.9).
UL 2054
1.1 These requirements cover portable primary (nonrechargeable) and secondary (rechargeable) batteries for use as power sources in products. These batteries consist of either a single electrochemical cell or two or more cells connected in series, parallel, or both, that convert chemical energy into electrical energy by chemical reaction.
ANSI C18.2M Part 1-2013
Applies to portable rechargeable or secondary cells and batteries based on the following electrotechnical systems: nickel cadmium, nickel metal hydride and lithium ion.
ANSI C18.2M Pt 2-2014
ANSI C18.4M-2017
This standard sets forth some general considerations that should be taken into account when developing battery standards that balance the need to achieve the intended product performance while reducing adverse environmental effects, and outlines ways in which provisions in battery standards might affect the environment during the stages of its life cycle.
CAN/CSA-E61959:14
This International standard specifies tests and requirements for verifying the mechanical behaviour of sealed portable secondary cells and batteries during handling and normal use. Relevant national and International standards have been taken into consideration.
ACI 318M-14
1.1.1 — This code provides minimum requirements for design and construction of structural concrete elements of any structure erected under requirements of the legally adopted general building code of which this code forms a part. In areas without a legally adopted building code, this code defines minimum acceptable standards of design and construction practice.
ANSI Z21.13-2017/CSA 4.9-2017
1.1
This Standard applies to newly produced gas-fired low-pressure steam and hot water boilers with gas inlet pressure ratings not exceeding 0.5 psi (3.5 kPa) and having input ratings of less than 12,500,000 Btu/hr (3 663 389 W) (see Clause 3, Definitions), hereinafter referred to as boilers*, constructed entirely of new unused parts and materials, for operation at or below the following pressures and temperatures:
Steam heating boilers
15 psi (103.42 kPa) steam pressure
Hot water heating boilers