| DGTIR-100 (2014) | BC Hydro provides a means for distribution-connected customers to connect a small energy source to the BC Hydro Distribution System to offset their load and participate in the Net Metering program (RS1289) or other energy procurement offers. This document contains the… |
| AB - Interconnection Guide (2002) | The Alberta Distributed Generation Interconnection Guide provides guidelines for connecting a generation facility to the Alberta Interconnected Electric System (AIES) via a Wires Owner’s distribution system, and assists in determining the technical and operating requirements… |
| CAN/CSA-C22.3 NO. 9-08 (R2015) | 1.1 This Standard specifies the technical requirements for the interconnection of distributed resources (DR) and distribution systems up to 50 kV line to line. This Standard covers all distributed resource technologies with an aggregate capacity of 10 MW or less at the point… |
| C22.2 NO. 47-13 | 1.1 This Standard applies to single-phase and polyphase transformers of the dry type for supplying energy to power, heating, and lighting circuits and designed to be installed and used in accordance with the Canadian Electrical Code, Part I. 1.2 This Standard applies to… |
| CAN/CSA-C22.2 NO. 257-06 (R2015) | 1.1 This Standard specifies the electrical requirements for safe interconnection of inverter-based micro-distributed resource (micro-DR) systems to low-voltage systems connected to distribution systems. The output of these systems is limited to 600 V (nominal) or less (single… |
| AS/NZS 4777.2:2015 | Specifies minimum performance and safety requirements for the design, construction and operation of inverters intended for use in inverter energy systems for the inj |
| 29 CFR 1926.441 | (a) General requirements—(1) Batteries of the unsealed type shall be located in enclosures with outside vents or in well ventilated rooms and shall be arranged so as to prevent the escape of fumes, gases, or electrolyte spray into other areas. (2) Ventilation shall be… |
| NFPA 3 | This recommended practice provides the recommended procedures, methods, and documentation for commissioning and integrated testing of active and passive fire protection and life safety systems and their interconnections with other building systems. |
| IEEE Std C62.22-2009 | The guide covers the application of metal-oxide surge arresters to safeguard electric power equipment, with a nominal operating voltage 1000 V and above, against the hazards of abnormally high-voltage surges of various origins. It also provides information on the… |
| IEC 60870-5-5:1995 | Applies to telecontrol equipment and systems with coded bit serial data transmission for monitoring and controlling geographically widespread processes. It defines a telecontrol companion standard that enables interoperability among compatible telecontrol equipment. |