DC Components
Category out of scope of this review, however kept as a place holder for relevant CSR and lesson-learned
IEEE Std 1375-1998
This guidance provides for the protection of stationary battery systems, which include the battery and DC components to and including the first protective device downstream of battery terminals. Recommendations are not intended to set requirements; rather, they present options to the battery system designer concerning the types of protection available.
AS 2676.1-1992
Abstract: Sets out recommended practices for the installation, maintenance, testing and replacement of vented secondary batteries permanently installed in buildings.
Scope:
This Standard sets out recommended practices for the installation, maintenance, testing and replacement of vented secondary batteries permanently installed in or on buildings. It also provides guidance to determine when batteries should be replaced.
AS/NZS - 3000 (2007)
The standard sets out requirements for the design, construction and verification of electrical installations, including the selection and installation of electrical equipment forming part of such electrical installations. These requirements are intended to protect persons, livestock, and property from electric shock, fire and physical injury hazards that may arise from an electrical installation that is used with reasonable care and with due regard to the intended purpose of the electrical installation.
IEC 61000-6-1
There are various sub standards (6-1, 6.-2, etc.) that apply to EMC. Information from IEC 61000-6-1 covers EMC immunity requirements for electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be performed at frequencies where no requirements are specified. This generic EMC immunity standard is applicable if no relevant dedicated product or product-family EMC immunity standard exists.
NFPA 70E
NFPA 70E requirements for safe work practices to protect personnel by reducing exposure to major electrical hazards. Originally developed at Occupational Safety and Health Administration (OSHA)’s request, NFPA 70E helps companies and employees avoid workplace injuries and fatalities due to shock, electrocution, arc flash and arc blast, and assists in complying with OSHA 1910 Subpart S and OSHA 1926 Subpart K.
NFPA 850
The document outlines fire safety recommendations for gas, oil, coal, and alternative fuel electric generating plants, including high voltage DC converter stations and combustion turbine units used for electric generation. Fire prevention and fire protection recommendations advance the safety of construction and operating personnel, physical integrity of plant components, and the continuity of plant operations.
C22.1-15
CAN/CSA-C22.2 NO. 0-10 (R2015)
Intended Use
The objective of Standards issued as part of the Canadian Electrical Code, Part II, is to give consideration to the prevention of injury to persons and damage to property through proper design, good construction, and high quality of work. These safety Standards are intended to provide requirements for the design and construction of electrical equipment, primarily to address fire and electrical shock hazards and for use throughout Canada in conformity with the rules of the Canadian Electrical Code, Part I.
IEEE Std 946-2004
Description: Revision of IEEE Std 946-1992 Guidance for the design of the DC auxiliary power systems for nuclear and non-nuclear power generating stations is provided by this recommended practice. The components of the DC auxiliary power system addressed by this recommended practice include lead-acid storage batteries, static battery chargers, and distribution equipment.