IEC 60622:2002

Identifier
IEC 60622:2002
Title
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells
Type of Document
Standard
Publisher
Edition Date
2002 Oct 10
Summary

The standard specifies marking, tests and requirements for sealed nickel cadmium prismatic secondary single cells.

IEC 60623:2017

Identifier
IEC 60623:2017
Title
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
Type of Document
Standard
Publisher
Edition Date
2017 Jan 23
Summary

The standard specifies marking, designation, dimensions, tests and requirements for vented Nickel Cadmium prismatic secondary single cells.

IEC 60896-11:2002

Identifier
IEC 60896-11:2002
Title
Stationary lead-acid batteries - Part 11: Vented types - General requirements and methods of tests
Type of Document
Standard
Publisher
Edition Date
2002 Dec 04
Summary

This part of IEC 60896 is applicable to Lead-Acid cells and batteries which are designed for service in fixed locations and which are permanently connected to the load and to the DC power supply. Part 11 of the standard is applicable to vented types only. The object of this standard is to specify general requirements and main characteristics with corresponding test methods associated with all types and construction modes of Lead-Acid stationary batteries, excluding valve-regulated types.

IEC 60896-21:2004

Identifier
IEC 60896-21:2004
Title
Stationary lead-acid batteries - Part 21: Valve regulated types - Methods of test
Type of Document
Standard
Publisher
Edition Date
2004 Feb 05
Summary

Applies to all stationary Lead-Acid cells and monobloc batteries of the valve regulated type for float charge applications (i.e., permanently connected to a load and to a DC power supply), in a static location and incorporated into stationary equipment or installed in battery rooms for use in telecom, UPS, utility switching, emergency power or similar applications. The objective is to specify test methods for all types and construction of valve regulated stationary Lead-Acid cells and monobloc batteries used in standby power applications.

Type of ES Technology
ES Main Coverage
Site, Building and Enclosure Coverage

IEC 60896-22:2004

Identifier
IEC 60896-22:2004
Title
Stationary lead-acid batteries - Part 22: Valve regulated types - Requirements
Type of Document
Standard
Publisher
Edition Date
2004 Feb 05
Summary

Applies to all stationary Lead-Acid cells and monobloc batteries of valve regulated type for float charge applications, (i.e., permanently connected to load and DC power supply), in a static location and incorporated into stationary equipment or installed in battery rooms for use in telecom, UPS, utility switching, emergency power or similar applications.

IEC 61427-1:2013

Identifier
IEC 61427-1:2013
Title
Secondary cells and batteries for renewable energy storage - General requirements and methods of test - Part 1: Photovoltaic off-grid application
Type of Document
Standard
Publisher
Edition Date
2013 Apr 23
Summary

This international standard provides general information about secondary batteries used in PVES and the typical methods of test used for the verification of battery performance. This standard does not include specific information relating to battery sizing, method of charge or PVES design. NOTE: This standard is applicable to Lead-Acid and Nickel Cadmium cells and batteries. This standard will be amended to include other electrochemical systems when they become available.

IEC 62259:2003

Identifier
IEC 62259:2003
Title
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Nickel-cadmium prismatic secondary single cells with partial gas recombination
Type of Document
Standard
Publisher
Edition Date
2003 Oct 27
Summary

The standard specifies marking, designation, dimensions, tests and requirements for vented Nickel Cadmium prismatic secondary single cells where special provisions have been made in order to have partial or, under very specific conditions, full gas recombination.

ES Main Coverage
Site, Building and Enclosure Coverage

IEC 62485-2:2010

Identifier
IEC 62485-2:2010
Title
Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries
Type of Document
Standard
Publisher
Edition Date
2010 Jun 16
Summary

This part of the IEC 62485 applies to stationary secondary batteries and battery installations with a maximum voltage of DC 1 500 V (nominal) and describes the principal measures for protections against hazards generated from electricity, gas emission, and electrolyte.

IEC 62619:2017

Identifier
IEC 62619:2017
Title
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Safety requirements for secondary lithium cells and batteries, for use in industrial applications
Type of Document
Standard
Publisher
Edition Date
2017 Feb 13
Summary

The standard provides requirements on safety aspects associated with the erection, use, inspection, maintenance and disposal of cells and batteries for stationary applications and motive (other than on-road vehicle). Under development moving toward the committee draft voting stage. Includes safety requirements for lithium-ion cells for stationary and off-road motive applications and some battery requirements (evaluation of battery and battery management system [BMS] combination). Not a system standard, as it covers only battery and BMS interaction.

IEC 62620:2014

Identifier
IEC 62620:2014
Title
Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary lithium cells and batteries for use in industrial applications
Type of Document
Standard
Publisher
Edition Date
2014 Nov 25
Summary

The standard specifies marking, designation, dimensions, tests and requirements for large format lithium-ion secondary single cells and batteries used in Industrial Applications including Stationary applications.