| Norme CEI 61427-2:2015 | La norme CEI 61427-2:2015 concerne les batteries secondaires utilisées dans les applications de stockage d'énergie électrique (SEE) en réseau et fournit les méthodes d'essai associées pour la vérification de leur endurance, de leurs propriétés et de leurs performances… |
| IEC 60993:1989 | This standard applies to electrolytes and their components when used in vented nickel-cadmium cells. These electrolytes are used: for filling cells supplied without filling electrolyte, and/or, for refilling cells if change of electrolyte is required, and/or, if the operating… |
| Norme CEI 60993:1989 | Cette norme s'applique aux électrolytes et à leurs composants lorsqu'ils sont utilisés dans des piles nickel-cadmium ventilées. Ces électrolytes sont utilisés : pour le remplissage des cellules fournies sans électrolyte de remplissage, et/ou, pour le remplissage des cellules… |
| UL 1741 | 1.1 These requirements cover inverters, converters, charge controllers, and interconnection system equipment (ISE) intended for use in stand-alone (not grid-connected) or utility-interactive (grid-connected) power systems. 1.2 For utility-interactive equipment, these… |
| UL 2580 | 1.1 These requirements cover electrical energy storage assemblies such as battery packs and combination electrochemical capacitor assemblies and modules that make up these assemblies for use in electric-powered vehicles as defined in this standard. |
| UL 1973 | Safety standard for stationary batteries for energy storage applications, non-chemistry specific and includes electrochemical capacitor systems or hybrid electrochemical capacitor and battery systems. Includes requirements for unique technologies such as flow batteries and… |
| UL 1642 | 1.1 These requirements cover primary (nonrechargeable) and secondary (rechargeable) lithium batteries for use as power sources in products. |
| UL 810A | 1.1 These requirements cover electrochemical capacitors for use in equipment such as electronic products, uninterruptible power supplies, emergency lighting, engine starting, and power equipment. These energy storage capacitors, also known as electric double-layer capacitors… |
| UL 489 | 1.1 This standard covers molded-case circuit breakers, circuit-breaker and ground-fault circuit interrupters, fused circuit breakers and accessory high-fault protectors. These circuit breakers are specifically intended to provide service entrance, feeder and branch circuit… |
| GR-4228 | The document provides a 3-level system of VRLA String Safety and Performance Criteria based on Telcordia generic requirements documents. The VRLA string criteria levels are defined as follows: ? Level 1, Safety and Minimal Operability – minimum acceptable level of compliance… |